PV connectors 1500V 43A - PV solar cable wire connectors compatible with Staubli MC4 Evo2

Solar PV Connectors 1500V 43A - PV Solar Cable Wire Connectors Compatible with Staubli MC4 Evo2

PV-TY 008-5
PV Connectors for Solar Panels
Core Technical Advantages (20-Year Expertise) + 20-year PV manufacturing + full-process control
• ±0.01mm precision hand assembly + 100% QC (zero PIN misalignment)
• TUV-certified (IEC 62852): 43A & 1500V DC
• -40°C~+85°C + IP68 protection
• PA66+tin-plated copper → 25-year lifespan
• Polarized anti-misinsertion + snap-lock (tool-only unlock)
• Tool-free assembly (50% faster) + 2min quick replacement
• 2.5-6mm² cable compatibility (all mainstream modules)
• 1500V high-voltage support
• 100k+ units/day output + 1-15 day lead times
• Pros/DIY-friendly: low insertion force + intuitive operation
Quantity:
Contact Now
add to cart
   Drawing   
 
          drawing for solar pv connector
   Technical Data Sheet   
 
Solar PV Connectors PV-TY008 Technical Data Sheet
solar pv connector-1500VDC43A-TUV certified-TYOU brand
    Type  Φ4.0mm PV Connector
  Rated Voltage  1500V DC
  Rated Current  43A
    Rated Impulse Voltage  16kV
    Rated Insulation Voltage   8kV
    Contact Resistance   0.5mΩ
    Protection Class   Class ‖
    Pollution Class   2
    Insulation Material   PPE/PPO/PA
    Contact Material   Copper, Tin-Plated
    Temperature Range   -40℃ to +85℃
    Flame Resistance    UL94_V0  5VA
    Upper Limiting Temperature   100 
    Cable Size   2.5mm2, 4.0mm2, 6.0mm2
    Application Class    A
    Over Voltage Category    III
    Relative Humidity    85%
    Pin Dimensions    Φ4.0mm
    Operating Cycles    100
    Sealing Material    Silicon Rubber
    Reference Standard    IEC 62852 / EN 62852
    Approval    TUV R 50585814
 
   TUV CERTIFICATE    
 TUV Rheinland / Certificate No. R 50585814 
 web site : www.tuv.com 
 https://www.certipedia.com/certificates/50585814?locale=zh-CN
TUV certificate of solar PV connector-1500VDC43A
 

   How to Ensure the Production of TUV-Standard Solar PV Connectors ?   

precision molds of solar PV connector   Logo marking on the mold of solar PV connector

               ( PV-TY008  mold )                          ( Logo marking on the mold - OEM for clients )

With 20 years of PV manufacturing experience, TYOU engineers every solar PV connectors from mold to assembly with uncompromising precision.

Mold Design – The DNA of  Solar PV Connectors
Micron-level tolerances (±0.005 mm) and CAE mold flow analysis ensure each solar pv connectors cavity fills perfectly, avoiding short shots, warpage, and weld lines. Shrinkage is pre-compensated (PC/PE/PP 0.6%, PA 0.8%), and high-performance SKD61 steel (HRC 60, corrosion ≤0.03 mm/year) gives the solar PV  cable connectors mold a lifespan exceeding 1 million cycles. This steel choice is fundamental for  solar PV connectors that demands long-term dimensional stability. DLC-coated surfaces and 5-axis CNC machining (0.002 mm capability) further refine every housing.

Material Science – Engineering the 25-Year Solar PV Connectors
We select halogen-free, flame-retardant PA66/PPO so the PV connectors housing withstands 85°C/85% RH, -40°C impacts (1 J, no cracking), and UV aging (xenon 1000 h, tensile strength retention ≥80%). Incoming resin is tested for MFR (15 g/10 min), CTI ≥600 V, and dielectric strength ≥20 kV/mm, guaranteeing consistent raw material quality for all solar PV connectors.

Terminal Integrity – The Electrical Heart of the Solar PV Connectors
Our PV wire connectors terminals employ high-elasticity copper alloy, bright tin plating (3–8 µm), and a four-arm elastic cage structure that ensures redundant contact paths. With contact force ≥20 N and insertion force ≤80 N, IEC 60512 testing proves the solar pv connectors maintains contact resistance ≤0.5 mΩ even after 200 thermal cycles and 72-hour salt spray. Third-party TÜV/UL reports confirm the PV solar connectors are built for 25 years of uninterrupted field performance.

( TUV website: www.tuv.com; UL website : www.ul.com; GB/T website: https://openstd.samr.gov.cn/bzgk/gb/index)

Assembly: Pre-assembly gaps, insertion depth, and tightening torque are all validated to lock in the reliability of every unit.
 

    Installation Show   
installation-solar pv connectors for solar panels